DTC B212D-16 Dodge
Ignition Run Only Input Circuit Voltage Below Threshold
Ignition Run Only Input Circuit Voltage Below Threshold
Description
The Occupant Restraint Controller (ORC) receives power from both a battery and ignition feed input circuit from the TIPM. These circuits power the ORC and the capacitors used to initiate the squib deployment circuits in the event of collision detection.
Cause and Solution
ACTIVE POWER DISTRIBUTION CENTER RUN RELAY TROUBLE CODES(F100) RUN RELAY CIRCUIT OPENTIPM FUSE (M32) OPEN(F100) FUSED RUN RELAY OUTPUT CIRCUIT OPEN OR SHORTED TO GROUNDOCCUPANT RESTRAINT CONTROLLER (ORC)
Circuit Voltage Below Threshold
This sub type is used for failures, where the control module measures a voltage below a specified range but not necessarily a short to ground.
Video Guide
Diagnostic Info
- DTC Code: B212D-16
- Brand: Dodge