DTC P2248 Dodge
O2 Sensor 2 1 Reference Voltage Performance
O2 Sensor 2 1 Reference Voltage Performance
Description
The wide-band O2 Sensor operates differently than traditional O2 Sensors. The wide-band O2 Sensor tip consists of two cells that provide different functions, a measurement chamber and a detection chamber with pumping capabilities. The oxygen pumping function is the ability to pump oxygen into or out of the measurement chamber depending on the level of oxygen in the measurement chamber. This function provides the wide-band sensing capabilities and is critical for proper oxygen measurement. The O2 Sensor Reference circuit provides a common bias supply to both the O2 Sensor Signal and the O2 Sensor Pump Cell Current circuits.
Cause and Solution
O2 2 1 RETURN CIRCUIT OPEN OR HIGH RESISTANCEO2 SENSOR 2 1POWERTRAIN CONTROL MODULE (PCM)
Video Guide
Diagnostic Info
- DTC Code: P2248
- Brand: Dodge