DTC C1202-01 Fiat
Vacuum Sensor Fault - General Electrical Failure
Vacuum Sensor Fault - General Electrical Failure
Description
Vacuum Sensor Signal voltage level is below 0.1 volt for 100 msec. Vacuum Sensor Signal indicating voltage above 3.5 volts for 100 msec.
Cause and Solution
Vacuum Pressure Sensor Supply Circuit Open Or High Resistance
Vacuum Pressure Sensor Signal Circuit Shorted To Voltage
Vacuum Pressure Sensor Signal Circuit Shorted To Ground
Vacuum Pressure Sensor Signal Circuit Open Or High Resistance
Vacuum Pressure Sensor Return Circuit Open Or High Resistance
Vacuum Pressure Sensor
Anti-Lock Brake System (Abs) Module
General Electrical Failure
Video Guide
Diagnostic Info
- DTC Code: C1202-01
- Brand: Fiat