DTC P0403 Lincoln

EGR A Control Circuit Open

EGR A Control Circuit Open

Description

The exhaust gas recirculation (EGR) system is continuously monitored to check the four electric EGR motor coils, circuits, and the PCM for opens, shorts to voltage and ground. If a concern is detected, the EGR system is disabled and additional monitoring is suspended for the remainder of the drive until the next drive cycle.

Cause and Solution

Electric EGR stepper motor windings openElectric EGR connector not seated correctlyEGRMC circuit openEGRMC circuit short to voltageEGRMC circuit short to groundDamaged PCM

Video Guide

Duration: PT4M19S | Uploaded: 2020-07-16

Diagnostic Info

  • DTC Code: P0403
  • Brand: Lincoln
Back to Blog