DTC P024B Alfa Romeo

Charge Air Cooler Bypass Control A Stuck

Charge Air Cooler Bypass Control A Stuck

Description

The Powertrain Control Module (PCM) monitors for a change in the Low Temperature Coolant Temperature Sensor and determines that the Coolant Bypass Valve is stuck open.

Cause and Solution

Low Coolant Level Or Air In Cooling System
Restriction In Low Temperature Cooling System Plumbing
Restriction In Intercooler
Restriction In The Low Temperature Cooling System Radiator
Coolant Bypass Valve Mechanically Stuck Open

Video Guide

Duration: PT4M6S | Uploaded: 2020-04-28

Diagnostic Info

  • DTC Code: P024B
  • Brand: Alfa Romeo
Back to Blog