DTC U2016 Lincoln

EVAP System Small Leak Detected

EVAP System Small Leak Detected

Description

ECT Sensor from 40-90ºF and within 10ºF of the BTS input at startup (cold engine), fuel level more than 1 2 full, engine started, EVAP leak test enabled, and the PCM detected a leak greater than 0.040 but less than 0.080 somewhere in the EVAP system.

Cause and Solution

EVAP fuel tank or canister vapor hoses leaking or damagedEVAP system component leaking, damaged or has failedFuel tank cap is loose, or the cap release pressure is incorrectLeak detection pump damaged or leaking

Video Guide

Duration: PT4M16S | Uploaded: 2020-07-27

Diagnostic Info

  • DTC Code: U2016
  • Brand: Lincoln
Back to Blog