DTC P1532 Subaru

Primary Brake Pressure Sensor Signal Out Of Range

Primary Brake Pressure Sensor Signal Out Of Range

Description

Case 1 Sensor Supply Voltage A failure is detected if the external sensor supply voltage is out of the 5.0±0.1V for more than 50ms. Case 2 Pressure Sensor Signal A failure is detected if the output voltage is in the lower fault area ( 0.0V lt; pressure sensor output voltage lt; 0.25V ) for 0.1s. A failure is detected if the output signal is in the upper fault area ( 4.75V lt; pressure sensor output voltage lt; 5.0V ) for 0.1s and a positive signal step of Δoutput signal gt; 46.0 V s was detected. A failure is detected if the output signal is in the upper fault area ( 4.75V lt; pressure sensor output voltage lt; 5.0V ) for 0.5s and no positive signal step was detected. A failure is detected if the output signal is in the upper fault area ( 4.75V lt; pressure sensor output voltage lt; 5.0V ) for 60s and the output voltage of the redundant pressure sensor is higher than 2.8 V.

Cause and Solution

Open or short of pressure sensor circuit Faulty pressure sensor Faulty HECU

Video Guide

Duration: PT4M56S | Uploaded: 2020-06-23

Diagnostic Info

  • DTC Code: P1532
  • Brand: Subaru