DTC P0139 Audi

O2 Circuit Slow Response (Bank 1, Sensor 2)

O2 Circuit Slow Response (Bank 1, Sensor 2)

Description

rich voltage, > =547.9 mV lean voltage < =201.2 mV OR Max O2 mass flow (disable), > =5000 mg O2S rear, ready fuel cut-off, ready front O2 sensor, lambda signal, >2.00 modeled exhaust gas temp. >400° C exhaust gas mass flow, >25.0 kg h rear O2 sensor internal resistance, < =700Ω or resistance measurement, ready front O2 sensor, sensor cross change, no fault rear O2 sensor heater, wires and oscillating check, no fault purge valve, no fault trigger for step change, delta transient time, >0

Cause and Solution

HO2S Fuses
HO2S terminal corrosion
Open between HO2S and Power supply relay
Open or Short? between HO2S and ECM
Faulty HO2S

Video Guide

Duration: PT4M46S | Uploaded: 2020-04-29

Diagnostic Info

  • DTC Code: P0139
  • Brand: Audi
Back to Blog