O2 Sensor Circuit (Bank 2-Sensor 2) Short to B+

O2 Sensor Circuit (Bank 2-Sensor 2) Short to B+

Description

Engine started, battery voltage must be at least 11.5v, all electrical components must be off, the ground between the engine and the chassis must be well connected, the exhaust system must be properly sealed between the catalytic converter and the cylinde

Cause and Solution

Oxygen sensor (before catalytic converter) is faulty
Oxygen sensor (behind catalytic converter) is faulty
Oxygen sensor heater (before catalytic converter) is faulty
Oxygen sensor heater (behind catalytic converter) is faulty

Video Guide

Duration: PT4M | Uploaded: 2020-06-20

Diagnostic Info

  • DTC Code: P1110
  • Brand: Audi