DTC P1515 Audi

Intake Manifold Changeover Valve Circuit Short to Ground

Intake Manifold Changeover Valve Circuit Short to Ground

Description

Engine started, and the ECM detected the changeover valve circuit was shorting to ground during the continuous self test.

Cause and Solution

Leaky vacuum reservoir, vacuum lines loose or damaged
Vacuum solenoid or vacuum actuator is damaged
IMRC actuator cable gears are seized, or the cables are improperly routed or seized