DTC P2540 BMW

Secondary Air System Vent Valve Stuck Closed

Secondary Air System Vent Valve Stuck Closed

Description

Engine started, battery voltage must be at least 11.5v, all electrical components must be off, parking brake must be engaged (to keep daytime driving lights off), automatic transmission selector must be in park, the exhaust system must be properly sealed

Cause and Solution

EVAP power supply circuit is open
EVAP solenoid control circuit is open or shorted to ground
EVAP solenoid control circuit is shorted to power (B+)
EVAP solenoid valve is damaged or it has failed

Video Guide

Duration: PT4M15S | Uploaded: 2020-06-20

Diagnostic Info

  • DTC Code: P2540
  • Brand: BMW
Back to Blog