DTC P0974 Acura

Open in Shift Solenoid Valve A Circuit

Open in Shift Solenoid Valve A Circuit

Description

The return signal does not match the command to turn OFF shift solenoid valve A for at least 1 second. The execution time is continuous and the duration time is 1 seconds or more. DTCs P0973, P0982, P0983 are not active. NOTE: This code is caused by an electrical circuit problem and cannot be caused by a mechanical problem in the transmission.

Cause and Solution

Poor connections or loose terminals at shift solenoid valve A and the PCM
Open in the wire between PCM connector terminal and the shift solenoid harness connector
Faulty shift solenoid valve A or shift solenoid harness
PCM may need to be updated with the latest software

Video Guide

Duration: PT4M23S | Uploaded: 2020-04-18

Diagnostic Info

  • DTC Code: P0974
  • Brand: Acura
Back to Blog