DTC P1B17 Chevrolet

Output Air Temperature Sensor 3 Circuit Short to Ground

Output Air Temperature Sensor 3 Circuit Short to Ground

Description

Ignition ON.

Cause and Solution

The HVAC control module detects the temperature sensor signal circuit is less than -36°C (-38°F) or greater than 215°C (419°F) for greater than 15 seconds.

Video Guide

Duration: PT3M47S | Uploaded: 2020-06-21

Diagnostic Info

  • DTC Code: P1B17
  • Brand: Chevrolet
Back to Blog